Aarhus University Seal

Determining the Precise Surface Area of Gold Catalysts Without Altering Them

Knowing the true surface area of a catalyst is essential when comparing catalytic performance. A new study from Aarhus University shows that a copper-assisted electrochemical measurement method can determine the active surface area of gold electrocatalysts in a reliable and non-destructive way.

Comparison of single-crystalline gold, polycrystalline gold and gold nanoparticles, illustrating increasingly complex gold surfaces used in catalysis.

Gold is widely used in electrocatalysis, including studies related to carbon dioxide conversion and other reactions relevant for the sustainable energy transition. But to understand how well a gold catalyst performs, researchers first need to know how much of its surface is contributing to the reaction.

This is not always simple. Many catalysts are rough, porous or made from nanometer-sized particles deposited on a second, cheaper and inactive material. Their real surface area can be much larger than what is suggested by their outer dimensions, known as geometrical surface area. Errors in measuring this surface area can lead to an over- or underestimation of the catalyst's true performance.

A new study by Paul M. Leidinger and Jeppe V. Lauritsen from the Department of Chemistry at Aarhus University takes a closer look at this problem. The study compares a widely used gold oxidation method with a copper-based method that can be calibrated directly against atomic-scale surface measurements.

Key Findings

  • The activity of heterogeneous catalysts is determined by their surface, so assessing the real active surface area is essential.
  • The gold surface oxidation method modifies the surface it is trying to measure and is very sensitive to experimental inaccuracies.
  • Instead, copper atoms are electrochemically deposited on the gold surface and removed again. The charge required for this process can be directly related to the gold surface area.
  • Atomic-scale imaging and surface analysis were used to calibrate how much copper was deposited.
  • The study provides a clearer reference for future work on gold-based electrocatalysts.

Why the Active Surface Matters

In heterogeneous catalysis, reactions happen on the catalyst surface. This means that two samples made from the same material can seem to differ in activity if one has a much larger active surface than the other.

For electrocatalysts, researchers often report activity relative to the electrochemical surface area. This is the part of the active material surface that is accessible during an electrochemical reaction. It is especially important for rough, porous or nanostructured materials, where the real surface area can be much larger than the outer shape suggests.

For gold catalysts, this surface area is often estimated using electrochemical methods. But the study shows that the choice of method matters. One commonly used approach is based on forming and reducing a gold oxide layer. In this method, the gold surface is exposed to high potentials. The charge required to reduce the oxide is then used to estimate the surface area. The challenge is that these high potentials can modify the gold surface and the measured charge depends strongly on the chosen potential window. This makes the result particularly sensitive to small differences in how the measurement is performed

Copper as a Temporary Surface Marker

The study shows that copper underpotential deposition offers a more controlled alternative.

In this method, copper atoms are deposited on the gold surface at potentials where bulk copper would not normally form. The copper interacts with the gold surface and forms a characteristic, one-atom-thick layer. By measuring the charge needed to remove this copper again, it is possible to determine the gold surface area.

The advantage is that the method works at milder potentials than gold oxidation. This means that the gold surface is not oxidized and the original structure is better preserved.

Calibrating the Method Atom by Atom

To validate the method, the researchers needed to know how many copper atoms were deposited and how much charge was required to deposit a single copper atom.

They combined electrochemical measurements with surface-sensitive methods. Scanning tunneling microscopy was used to image copper on gold at the nanoscale. X‑ray photoelectron spectroscopy was used to measure the amount and chemical environment of copper on the surface.

This allowed the team to link the measured electrochemical charge to the amount of copper on the gold surface. The study found that the oxidation of one deposited copper atom in a chloride-containing electrolyte requires about one electron provided by the external electrical circuit.

This gives them a direct way to convert the measured electrical charge into the number of copper atoms on the surface, and from there into the gold surface area.

Why Does It Matter?

Reliable surface area measurements help researchers compare catalysts in a standardized way. They make it easier to see whether a catalyst is truly more active, or whether it simply has more exposed surface.

This is especially relevant for gold-based catalysts with complex structures, such as nanoparticles, foils, porous materials or nanostructured electrodes. These materials are important in electrocatalytic applications, but their true active surface area can be difficult to determine.

By providing a calibrated reference method, the study supports more comparable and reproducible electrocatalysis research. This can help researchers evaluate gold catalysts more accurately and build a stronger foundation for developing catalysts for sustainable chemical and energy technologies.


Interested?

You can explore the full review article and learn about the details in: 

[1] add link.

If you work with electrocatalysis, surface science or gold catalysts, we welcome collaborations and further discussion. Reach out to our Cluster Coordinator.